Start a Project

Request a Quote.

R Series · R Large

R Large Architectural LED Floodlights

Two large models with customizable power options

Compare R260 and R300, the two larger cylindrical housings in the R range. Review the references available for each mounting version before developing the installation detail.

Power
100 W / 120 W / 150 W (Customizable)
Maximum Luminous Flux
9,750 lm
LED Quantity
18, 20, 28, 48 or 60 LEDs
Base Mount Size
Ø283.8 × H350 mm
Model2 models

Project support: Review the model, beam, light colour and control for your installation.

Features & Specifications

R Large Features & Specifications

Power, output and dimensions below follow the selected model.

Large Cylindrical R Fixtures

R Large contains two cylindrical floodlight models with distinct housing and support dimensions. The complete assembly is relevant to architectural mounting positions.

Choose the model and mounting version together so the required clearance and fixture orientation can be assessed as one detail.

Select the beam for the intended surface and viewing direction. A larger cylinder does not, by itself, specify the reach of the lighting effect.

Performance & Optics

Power100 W / 120 W / 150 W (Customizable)
Maximum Luminous Flux9,750 lm
Maximum Luminous Efficacy65 lm/W
LED Quantity18, 20, 28, 48 or 60 LEDs
Lens DiameterØ45, Ø37 or Ø24 mm
LED Options3535 LED Cree XLamp XP-E OSRAM 3535 RGBW
Beam Angles10° · 15° · 30° · 45° · 65° · 10° × 60° · 20° × 40° · 20° × 60°

Light & Control

Color Temperature (CCT)2700–6000 K (factory-set; specify when ordering)
Light ColorWhite / Red / Green / Blue / Amber / RGB / RGBW
Control OptionsDMX512 · Wireless DMX · ON/OFF
Housing FinishJet Black · Signal White · Anthracite Grey · White Aluminium · Custom colours on request
Warranty5 years
Service Life50,000 h

Mechanical & Electrical

Base Mount DimensionsØ283.8 × H350 mm
U-Bracket DimensionsØ284 × D218.69 × H330 mm
IP RatingIP66
IK RatingIK10
Input VoltageAC85–265V · 50–60Hz
Operating Temperature−40 °C to +50 °C

Model Comparison

Compare R Large Models

Compare the listed model differences, then use the corresponding installation reference. The model table is not a project lighting calculation.

Specification
Power100 W / 120 W / 150 W (Customizable)120 W / 150 W / 200 W (Customizable)
Maximum Luminous Flux9,750 lm13,000 lm
LED Quantity18, 20, 28, 48 or 60 LEDs24, 36, 60 or 72 LEDs
Lens DiameterØ45, Ø37 or Ø24 mmØ45, Ø37 or Ø24 mm
LED Options3535 LED Cree XLamp XP-E OSRAM 3535 RGBW3535 LED Cree XLamp XP-E OSRAM 3535 RGBW
Base Mount DimensionsØ283.8 × H350 mmØ325.5 × H367 mm
U-Bracket DimensionsØ284 × D218.69 × H330 mmØ325 × D230 × H394 mm

Model Selection Guide

R260

For R260, check which mounting drawings are available. If the proposed version lacks a dimensional reference, request it before finalising the fixing detail.

R300

Review R300 with the base or U-bracket drawing appropriate to the intended installation. Keep the selected version explicit in the project schedule.

Optical Options

R Large Optical Distribution

Compare circular and elliptical beam angles for R Large LED floodlights. View horizontal projection at 0° and estimated beam coverage at 10 m.

30° H × 30° VMedium · Circular distribution
Horizontal beam angle H30°
Vertical beam angle V30°

Target view

Equal scale · H / V
Illustrative beam footprint: 5.36 m wide × 5.36 m high at 10 m.

Perpendicular target plane · Beam shape illustration

Horizontal projection

Side view
Beam coverage at 10 mEstimated at nominal beam angles
Horizontal width≈ 5.36 m
Vertical height≈ 5.36 m

Beam shapes and dimensions are illustrative, not measured photometric data. Actual results depend on the selected optics, luminaire configuration, and installation conditions.

Technical Documents

Technical Documents

Product specifications and technical files for your lighting project.

Product Family Datasheet

R Large · 2 models

Preview specifications and dimensions for this product family. The PDF opens in a new tab; download from the preview.

Preview Datasheet

Need More Technical Files?

Project-specific documentation

IES / LDT photometric files, installation guidance and CAD drawings can be requested from our product selection team.

Request Technical Files

FAQ

R Large Frequently Asked Questions

Questions about R Large model selection, configuration boundaries and the references needed before specification.

Which R Large size and mounting arrangement should I choose?

This group includes R260 / R300. Compare the listed power and the space available at the fixing surface. Base-mount and U-bracket versions have separate product and dimension references. Confirm the drawing for the required model and mounting version.

What changes between the base-mounted and U-bracket versions?

The seated base and side U-bracket use different mounting arrangements, so their overall height and fixing footprint must be checked separately. Viewing a U-bracket image does not confirm a base-mounted drawing or interchangeable hardware. Request an approved drawing for the exact model and version.

Which beam angles are shown for R Large LED floodlights?

The circular beam angles are 10°, 15°, 30°, 45° and 65°. The elliptical options are 10° × 60°, 20° × 40° and 20° × 60°, listed as short-axis angle × long-axis angle. Select the long-axis orientation in the preview to see the horizontal and vertical angles. Confirm the optic for the selected model and light-color configuration.

Which mounting and glare-control accessories are compatible with my model?

Base-mount and U-bracket product and drawing references are shown for the selected model. Confirm the model-specific mounting interface, fixing footprint and any optional glare-control accessory. A reference image does not establish supplied hardware or retrofit compatibility.

Which documents and project details should I include in a quote request?

Include the preferred model, mounting arrangement, quantity and target geometry, with an installation photo or drawing if available. Request the dimensioned drawing and electrical details for that exact version, plus configuration-specific IES/LDT data if needed. Model, mounting and accessory requirements can remain “Not sure yet”; unverified files are not presented as downloads.

What do the beam diagrams show?

The diagrams illustrate beam shape and horizontal projection. Actual light distribution depends on the selected model, optic and light-color configuration.

PROJECT SUPPORT

Discuss Your R Large Configuration

Share R260 or R300, the intended mounting version and the available support space. Request any missing mounting drawing and include target geometry rather than relying on the model size to describe the required effect.

CURRENT SELECTION · Selected Model: R260

HELPFUL INFORMATION

  • Light configuration
  • Control requirement
  • Preferred optic
  • Project drawing or reference image
  • Custom product requirements

CUSTOMIZATION SUPPORT

Project-specific customization can be reviewed based on your requirements, including product configuration, housing finish, control method, optics and other feasible modifications.

Our team will review your project information, selected model and customization requirements, then follow up with the available product options.

Request a Quote.