Start a Project

Request a Quote.

R Series · R Compact

R Compact Architectural LED Floodlights

Four compact models with customizable power options

Cylindrical LED floodlights for facade details and landscape features, with base or U-bracket mounting and selectable beam angles.

Power
12 W / 15 W / 18 W (Customizable)
Maximum Luminous Flux
1,170 lm
LED Quantity
4 or 6 LEDs
Base Mount Size
Ø120 × H175 mm
Model4 models

Project support: Review the model, beam, light colour and control for your installation.

Features & Specifications

R Compact Features & Specifications

Power, output and dimensions below follow the selected model.

Compact Cylindrical R Housings

R Compact includes four cylindrical floodlight sizes. Base and U-bracket views show different ways the selected fixture may be positioned.

Choose the mounting form with the available surface, clearance and target direction in mind. The housing dimensions and power listing remain tied to the model.

Keep the chosen base or bracket arrangement in the project schedule. Its fixing geometry should be coordinated with the architectural detail.

Performance & Optics

Power12 W / 15 W / 18 W (Customizable)
Maximum Luminous Flux1,170 lm
Maximum Luminous Efficacy65 lm/W
LED Quantity4 or 6 LEDs
Lens DiameterØ37 or Ø24 mm
LED Options3535 LED OSRAM 3535 RGBW
Beam Angles10° · 15° · 30° · 45° · 65° · 10° × 60° · 20° × 40° · 20° × 60°

Light & Control

Color Temperature (CCT)2700–6000 K (factory-set; specify when ordering)
Light ColorWhite / Red / Green / Blue / Amber / RGB / RGBW
Control OptionsDMX512 · Wireless DMX · ON/OFF
Housing FinishJet Black · Signal White · Anthracite Grey · White Aluminium · Custom colours on request
Warranty5 years
Service Life50,000 h

Mechanical & Electrical

Base Mount DimensionsØ120 × H175 mm
U-Bracket DimensionsØ120 × D96 × H153 mm
IP RatingIP66
IK RatingIK10
Input VoltageAC85–265V · 50–60Hz
Operating Temperature−40 °C to +50 °C

Model Comparison

Compare R Compact Models

Compare the listed model differences, then use the corresponding installation reference. The model table is not a project lighting calculation.

Specification
Power12 W / 15 W / 18 W (Customizable)18 W / 24 W (Customizable)24 W / 36 W (Customizable)36 W / 48 W (Customizable)
Maximum Luminous Flux1,170 lm1,560 lm2,340 lm3,120 lm
LED Quantity4 or 6 LEDs4 or 9 LEDs4 or 12 LEDs6, 8 or 18 LEDs
Lens DiameterØ37 or Ø24 mmØ37 or Ø24 mmØ37 or Ø24 mmØ37 or Ø24 mm
LED Options3535 LED OSRAM 3535 RGBW3535 LED OSRAM 3535 RGBW3535 LED Cree XLamp XP-E OSRAM 3535 RGBW3535 LED Cree XLamp XP-E OSRAM 3535 RGBW
Base Mount DimensionsØ120 × H175 mmØ131 × H183 mmØ147 × H194 mmØ164 × H265 mm
U-Bracket DimensionsØ120 × D96 × H153 mmØ131 × D104 × H163 mmØ147 × D115 × H183 mmØ164 × D133 × H200 mm

Model Selection Guide

R110

For R110, decide which mounting arrangement is being reviewed and use its matching drawing.

R120

Compare R120 with the adjacent compact models, keeping the selected base or U-bracket reference attached to the fixture schedule.

R135

Review R135 at the intended fixture position and check the drawing for the chosen mounting version.

R150

For R150, compare the complete mounting envelope as well as the model data before moving to the separate R Standard group.

Optical Options

R Compact Optical Distribution

Compare circular and elliptical beam angles for R Compact LED floodlights. View horizontal projection at 0° and estimated beam coverage at 10 m.

30° H × 30° VMedium · Circular distribution
Horizontal beam angle H30°
Vertical beam angle V30°

Target view

Equal scale · H / V
Illustrative beam footprint: 5.36 m wide × 5.36 m high at 10 m.

Perpendicular target plane · Beam shape illustration

Horizontal projection

Side view
Beam coverage at 10 mEstimated at nominal beam angles
Horizontal width≈ 5.36 m
Vertical height≈ 5.36 m

Beam shapes and dimensions are illustrative, not measured photometric data. Actual results depend on the selected optics, luminaire configuration, and installation conditions.

Technical Documents

Technical Documents

Product specifications and technical files for your lighting project.

Product Family Datasheet

R Compact · 4 models

Preview specifications and dimensions for this product family. The PDF opens in a new tab; download from the preview.

Preview Datasheet

Need More Technical Files?

Project-specific documentation

IES / LDT photometric files, installation guidance and CAD drawings can be requested from our product selection team.

Request Technical Files

FAQ

R Compact Frequently Asked Questions

Questions about R Compact model selection, configuration boundaries and the references needed before specification.

Which R Compact size and mounting arrangement should I choose?

This group includes R110 / R120 / R135 / R150. Compare the listed power and the space available at the fixing surface. Base-mount and U-bracket versions have separate product and dimension references. Confirm the drawing for the required model and mounting version.

What changes between the base-mounted and U-bracket versions?

The seated base and side U-bracket use different mounting arrangements, so their overall height and fixing footprint must be checked separately. Viewing a U-bracket image does not confirm a base-mounted drawing or interchangeable hardware. Request an approved drawing for the exact model and version.

Which beam angles are shown for R Compact LED floodlights?

The circular beam angles are 10°, 15°, 30°, 45° and 65°. The elliptical options are 10° × 60°, 20° × 40° and 20° × 60°, listed as short-axis angle × long-axis angle. Select the long-axis orientation in the preview to see the horizontal and vertical angles. Confirm the optic for the selected model and light-color configuration.

Which mounting and glare-control accessories are compatible with my model?

Base-mount and U-bracket product and drawing references are shown for the selected model. Confirm the model-specific mounting interface, fixing footprint and any optional glare-control accessory. A reference image does not establish supplied hardware or retrofit compatibility.

Which documents and project details should I include in a quote request?

Include the preferred model, mounting arrangement, quantity and target geometry, with an installation photo or drawing if available. Request the dimensioned drawing and electrical details for that exact version, plus configuration-specific IES/LDT data if needed. Model, mounting and accessory requirements can remain “Not sure yet”; unverified files are not presented as downloads.

What do the beam diagrams show?

The diagrams illustrate beam shape and horizontal projection. Actual light distribution depends on the selected model, optic and light-color configuration.

PROJECT SUPPORT

Discuss Your R Compact Configuration

Send the R Compact model and preferred base or U-bracket arrangement, along with the proposed fixing position. Include the target details and the drawing version you are reviewing.

CURRENT SELECTION · Selected Model: R110

HELPFUL INFORMATION

  • Light configuration
  • Control requirement
  • Preferred optic
  • Project drawing or reference image
  • Custom product requirements

CUSTOMIZATION SUPPORT

Project-specific customization can be reviewed based on your requirements, including product configuration, housing finish, control method, optics and other feasible modifications.

Our team will review your project information, selected model and customization requirements, then follow up with the available product options.

Request a Quote.