Start a Project

Request a Quote.

D Series · D Standard

D Standard Architectural LED Floodlights

Four models from 18–96 W for architectural lighting

Compare D130, D160, D180 and D210, the intermediate round housings in the D family. Use the model data and matching drawing version to review the fixture location before specification.

Power
18–36 W (Customizable)
Maximum Luminous Flux
2,340 lm
LED Quantity
12 pcs
Dimensions Without Hood
Ø130 × L136 × H172 mm
Model4 models

Project support: Review the model, beam, light colour and control for your installation.

Features & Specifications

D Standard Features & Specifications

Power, output and dimensions below follow the selected model.

Round D Housings in Four Sizes

Hood Options
D Standard offers four round housing sizes, each with a model-specific fixture envelope. Standard and hood forms provide different physical head choices.

Select the housing size alongside the target surface, available mounting space and desired beam. The listed output follows the chosen model.

Keep the selected head form in the fixture schedule so support, clearance and viewing direction can be considered together.

Performance & Optics

Power18–36 W (Customizable)
Maximum Luminous Flux2,340 lm
Maximum Luminous Efficacy65 lm/W
LED Quantity12 pcs
Beam Angles10° · 15° · 30° · 45° · 65° · 10° × 60° · 20° × 40° · 20° × 60°

Light & Control

Color Temperature (CCT)2700–6000 K (factory-set; specify when ordering)
Light ColorWhite / Red / Green / Blue / Amber / RGB / RGBW
Control OptionsDMX512 · Wireless DMX · ON/OFF
Housing FinishJet Black · Signal White · Anthracite Grey · White Aluminium · Custom colours on request
Warranty5 years
Service Life50,000 h

Mechanical & Electrical

Dimensions Without HoodØ130 × L136 × H172 mm
Dimensions With HoodØ130 × L181 × H172 mm
IP RatingIP66
IK RatingIK10
Input VoltageAC85–265V · 50–60Hz
Operating Temperature−40 °C to +50 °C
MaterialsADC12 aluminum alloy + weather-resistant silicone gasket + tempered glass

Model Comparison

Compare D Standard Models

Compare the listed model differences, then use the corresponding installation reference. The model table is not a project lighting calculation.

Specification
Power18–36 W (Customizable)36–48 W (Customizable)48–72 W (Customizable)72–96 W (Customizable)
Maximum Luminous Flux2,340 lm3,120 lm4,680 lm6,240 lm
LED Quantity12 pcs18 pcs24 pcs36 pcs
Dimensions Without HoodØ130 × L136 × H172 mmØ160 × L172 × H213 mmØ180 × L180 × H242 mmØ210 × L222 × H273 mm
Dimensions With HoodØ130 × L181 × H172 mmØ160 × L247 × H213 mmØ180 × L260 × H242 mmØ210 × L313 × H273 mm

Model Selection Guide

D130

Review D130 with the corresponding standard or hood reference and proposed fixing position.

D160

For D160, compare the model data with the target requirement while checking the available installation space.

D180

Use the D180 drawing for the intended version when preparing the mounting detail.

D210

Review D210 within the standard group before comparing D Large; keep its own model data on the schedule.

Optical Options

D Standard Optical Distribution

Compare circular and elliptical beam angles for D Standard LED floodlights. View horizontal projection at 0° and estimated beam coverage at 10 m.

30° H × 30° VMedium · Circular distribution
Horizontal beam angle H30°
Vertical beam angle V30°

Target view

Equal scale · H / V
Illustrative beam footprint: 5.36 m wide × 5.36 m high at 10 m.

Perpendicular target plane · Beam shape illustration

Horizontal projection

Side view
Beam coverage at 10 mEstimated at nominal beam angles
Horizontal width≈ 5.36 m
Vertical height≈ 5.36 m

Beam shapes and dimensions are illustrative, not measured photometric data. Actual results depend on the selected optics, luminaire configuration, and installation conditions.

Technical Documents

Technical Documents

Product specifications and technical files for your lighting project.

Product Family Datasheet

D Standard · 4 models

Preview specifications and dimensions for this product family. The PDF opens in a new tab; download from the preview.

Preview Datasheet

Need More Technical Files?

Project-specific documentation

IES / LDT photometric files, installation guidance and CAD drawings can be requested from our product selection team.

Request Technical Files

FAQ

D Standard Frequently Asked Questions

Questions about D Standard model selection, configuration boundaries and the references needed before specification.

How do I choose between the D Standard models?

This group includes D130 / D160 / D180 / D210. Compare the listed power, output and housing dimensions, then review the mounting space, target geometry and required light-colour configuration.

Why can the same D model have different lens layouts?

The same housing model can list separate lens diameters and LED quantities. The selected model’s configuration references reproduce these source records. Confirm the paired optic, rated power and electrical version; do not infer one optical layout from the exterior photo or the model-level LED count.

Which light-color and control options are available for my configuration?

The selection sheet lists RGB/RGBW with DMX512 or wireless DMX, Dual CCT with DMX512, Static White with DMX512, ON-OFF or ON-OFF-DALI, and Single Color with ON-OFF. Confirm the complete electrical and optical configuration for the selected model.

Is the housing material the same across the D Series?

D65 through D230 list ADC12 aluminum alloy, a weather-resistant silicone gasket and tempered glass. D300 lists magnesium alloy with the same gasket and front-cover materials. This material difference does not establish a performance advantage.

How do I confirm the correct drawing and available beam options?

Review the drawing for the exact model and housing version. The circular beam angles are 10°, 15°, 30°, 45° and 65°. The elliptical options are 10° × 60°, 20° × 40° and 20° × 60°, listed as short-axis angle × long-axis angle. Select the long-axis orientation in the preview to see the horizontal and vertical angles. Confirm the optic for the selected model and light-color configuration.

What information should I include in a project quote request?

Include your preferred model or describe the requirements if the model is undecided, your quantity and the installation location. Add the lighting target, any optical or control requirements, and project drawings or reference images. Our team will review the requested configuration rather than treating a viewed photo or beam example as an order specification.

What do the beam diagrams show?

The diagrams illustrate beam shape and horizontal projection. Actual light distribution depends on the selected model, optic and light-color configuration.

PROJECT SUPPORT

Discuss Your D Standard Configuration

Include the D Standard model and drawing version for each proposed fixture position. Share target dimensions and installation-space details so model selection can be reviewed in context.

CURRENT SELECTION · Selected Model: D130

HELPFUL INFORMATION

  • Light configuration
  • Control requirement
  • Preferred optic
  • Project drawing or reference image
  • Custom product requirements

CUSTOMIZATION SUPPORT

Project-specific customization can be reviewed based on your requirements, including product configuration, housing finish, control method, optics and other feasible modifications.

Our team will review your project information, selected model and customization requirements, then follow up with the available product options.

Request a Quote.