Third Generation · RG & YRY Covered

RG & YRY Covered Architectural LED Linear Lights

Square and curved light-transmitting covers in two 1000 mm profiles.

Choose a square or curved light-transmitting cover for a visible architectural lighting line. RG and YRY share a 1000 mm listed length, with different profile widths, power listings and control options. Select the exact model to view its specifications.

Power
12 W
Protection
IP66 · IK10
Beam Angle
120°
Profile
L1000 × W30 × H55 mm
Model2 models

Project support: Share the model, mounting detail, light requirements and project supply.

Features & Specifications

RG & YRY Covered Features & Technical Specifications

Profile dimensions and electrical options below follow the selected model.

Square and Curved Cover Profiles

RG and YRY share a covered linear-light format but use different face shapes. RG has a square light-transmitting cover, while YRY has a curved one.

The chosen cover changes the visible architectural line and profile envelope. Select the model around the available space and intended appearance.

Their output and control listings differ. Keep the requested light color and control with the chosen model rather than treating the two profiles as identical.

Performance & Optics

Power12 W
Maximum Luminous Flux960 lm
Luminous Efficacy80 lm/W
Beam Angle120°

Light & Control

Light ColorWhite / RGB / RGBW / Single colour on request
Color Temperature (CCT)2700 K / 3000 K / 4000 K
Control OptionsDMX512 / ON/OFF
Warranty5 years

Mechanical & Electrical

Dimensions (L × W × H)L1000 × W30 × H55 mm
IP RatingIP66
IK RatingIK10
Input voltage24 V DC
Operating Temperature−40 °C to +50 °C
Housing MaterialAluminium

RG & YRY Covered OPTICS

RG & YRY Covered Light Distribution

RG uses a square cover; YRY uses a curved cover. Both have a nominal 120° beam with white, RGB and RGBW options. Single-colour versions are available on request for RG.

Selected profile
Square light-transmitting cover
Light colour
White / RGB / RGBW / Single colour on request

BEAM GEOMETRY

Beam Diagram

RG & YRY Covered nominal 120 degree beam diagram Shared optical schematic for RG & YRY Covered LED linear lights, showing 60 degrees to each side of the centre axis. Profile illustration is schematic. Optical cover 60°60° 120° Nominal beam angle

Nominal beam schematic

REFERENCE PHOTOMETRY

Light Distribution Curve

C0–C180C90–C270 Luminous intensity (cd)

RG & YRY Covered Reference Curve

Full reference polar plot shown for RG & YRY Covered, including both C-plane curves and the 104.5 degree beam angle at 50 percent peak intensity.

Technical Documents

Technical Documents

Product specifications and technical files for your lighting project.

Product Family Datasheet

RG & YRY Covered · 2 models

Specifications and dimensions for all models on this product page.

Request Datasheet

Need More Technical Files?

Project-specific documentation

IES / LDT photometric files, installation guidance and CAD drawings can be requested from our product selection team.

Request Technical Files

FAQ

RG & YRY Covered Frequently Asked Questions

Practical questions about installation planning, samples and project specification.

Can a cover shape alone determine how the finished line will look?

No. Viewing direction, mounting position, joints and the adjacent surfaces also affect the appearance. Use a sample at the intended location when the visible light line is a critical design feature.

Can I order a run with RG and YRY mixed together?

Identify the model at each position and review the transition detail before combining them. Different face shapes and model listings should not be treated as interchangeable sections of one continuous profile.

What should I specify for a white-light order?

Provide the complete model code and the required white colour temperature. State whether all fixtures must share the same specified colour temperature and include the quantity for each model.

What information is needed to review the electrical layout?

Send the run lengths, fixture counts, available supply locations, cable route and intended control system. Cable sizing, voltage drop and power-supply selection require the actual project layout.

Are the product photos installation drawings?

No. They show the product construction. The listed dimensions can support an initial space check, but fixing positions and connection details require the matching installation drawing.

PROJECT SUPPORT

Discuss Your RG & YRY Covered Configuration

Share the selected model, required quantity, installation detail and lighting requirements. Include the supply and control information for a model-specific review.

CURRENT SELECTION · Selected Model: CAL-RG12-M1-C1

HELPFUL INFORMATION

  • Complete model code and required quantity
  • Light colour and optical requirements
  • Available supply and control requirement
  • Mounting detail, run length and cable route
  • Project drawing or reference photograph

PROJECT REVIEW

Our team will review your model, requested configuration and installation requirements, then follow up with the available options.

Request a Quote.